Owners Manual, Monaco 6000A, 6000N, 6002A, 6002N
Page 5 of 12 9700 B Owners Manual Monaco 6000.doc
8) Lower the fixture housing into the hole.
NOTE: Four (4) screws will be visible on outer trim ring when
installation is complete. The orientation of screws is
important, orient housing shown on pg 3. Trim ring screws
will be located at 12 o’clock, 3 o’clock, 6 o’clock and 9 o’clock,
relative to center of side-mounted wiring compartment.
Wiring compartment should be perpendicular to the wall or
illuminated surface.
9) With the housing setting in the hole, locate the three threaded
rod assemblies in the integral flange slots along the outer
edge of the housing. Temporarily attach two nuts to the top
of the threaded rods to protect the threads. Tap the top of the
rod assemblies to get them started in the ground. Remove the
housing from the hole. Continue driving the rods straight
into the ground until they are about 1 inch below the final
finished surface level.
NOTE: Do not drive rods too deep. If they are too deep they will
not reach the housing drive-over bracket at a later step.
10 Fill the bottom of the hole with 18 inches of drainage
material. Material shall be “select” free draining material
with a California Bearing Ration (CBR) of 20 or greater.
NOTE: Water will collect and drain through the bottom of the
fixture housing. Verify that water drainage through fixture bottom
will not adversely affect hardscape surrounding the fixture, or the
hardscape base.
RECESSED HOUSING INSTALLATION
11) Lower the fixture housing into the hole, with the three
threaded rods located in the flange slots. Add or remove
drainage material beneath the housing, until the top edge of
the housing is at the desired finished surface level.
12) Locate the top of the threaded rods in the appropriate
holes of the drive over brackets.
13) Place a 2” fender washer and ½-13 nut on each of the
threaded rods as shown in diagram. Run the washer
and nut down until it contacts the housing flange.
Tighten the nut snuggly.
14) Place a ½-13 nut on each of the threaded rods, on top and
bottom of the drive-over brackets as shown in diagram.
15) The threaded rods can be used to level the fixture. Adjust the
nuts on top and bottom of the brackets until the fixture is
level.
16) Run incoming power lines and connect conduit to selected
ports in the side-mounted wiring compartment using ¾” NPT
connectors (provided by others). Access the wiring
compartment by removing the cover. Twist counter-
clockwise to remove.
NOTE: Conduit connections must be sealed with waterproof
material to prevent water from leaking into the wiring
compartment.
NOTE: Leave at least 6” of wire extending from the conduit, for
later connection with the lamp module/ballast assembly.
17) Backfill the hole with soil as shown on page 5 or page 6.
NOTE: Final surface layer may be concrete or another material
such as asphalt, pavers, ect… If final surface is not concrete,
concrete must be applied below the final drive over surface as
shown in diagram on page 6.
18) Pour concrete as shown in diagram on page 5 or page 6.
19) Apply top surface layer, as shown on page 6, if other than
concrete.